BATTERIES
The combine is equipped with two 12 Volt batteries
(92 Ah). These are located at the back of the left-hand
side of the combine. Open cover 1 to have access to
the batteries.
The batteries can be disconnected completely by
means of the main battery switch 2.
IMPORTANT: To avoid loss of harvest data from the
InfoViewt
monitor, engine power reduction and/or
permanent InfoViewt monitor damage, it is strongly
recommended not to stop the engine by using the
battery switch. Always use the contact key in this
case.
IMPORTANT: It is advisable to disconnect the
batteries at the end of the day using the battery
switch.
The earth cable is connected to the negative (–)
battery terminals.
Check the acid level weekly (every 50 operating
hours), and, if necessary, fill with distilled water until
the separators are covered.
NOTE: Models CX860 and CX880 are also equipped
with two 12V batteries (92Ah), connected parallel, but
switching to 24 V during starting.
SECTION 4 – LUBRICATION AND MAINTENANCE