SECTION 2 – CONTROLS, INSTRUMENTS AND OPERATION

Calibration of the Concave position

To achieve a correct read out of the concave position
on the InfoViewt monitor, after changing or rework
of the concave, a calibration is necessary.
To calibrate the concave position, proceed as follows:
1. Select the "Concave position" calibration window.
Message: "Select proper concave type before
continuing"
2. To select the concave type refer to :
"13.Threshing" of this paragraph.
Message: "Then press enter".
3. Press "enter" to continue or "esc" to close the
calibration window.
Message: "Calibration initiated".
Message: "Calibration started, adjust actual
concave clearance to: XX mm".
Message: "Then press enter".
4. Adjust the concave clearance with the concave
clearance rocker switch to the requested physical
distance and press enter.
Remark: XX mm is 10 mm (3/8") for a grain concave,
17 mm (43/64") for a rice concave and
25 mm (15/16") for a maize concave.
Message: "Calibration successful".
5. The calibration is done.
6. Press "Enter" or "Esc" to close the calibration
window.