Sony DVCAM DSR-PDX10 Service Manual page 233

Hide thumbs Also See for DVCAM DSR-PDX10:
Table of Contents

Advertisement

DSR-PDX10/PDX10P
3. Serial No. Input
Note: Before performing the adjustments, check the data of page: 0,
address: 10 is "00". If not, set data: 00 to this address.
3-1. Company ID Input
Write the company ID in the EEPROM (nonvolatile memory).
Page
Address
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Input the following data to page: 8, addresses: 8C to 90.
Note: Press the PAUSE button of the adjustment remote commander
each time to set the data.
Address
8C
8D
8E
8F
90
3) Select page: 0, address: 01, and set data: 00.
8
8C, 8D, 8E, 8F, 90
Data
08
00
46
01
02
3-2. Serial No. Input
Write the serial No. and model code in the EEPROM (nonvolatile
memory). Convert the serial No. on the name plate from decimal to
hexadecimal, and write in the EEPROM.
Page
Address
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Read the serial No. on the name plate, and take it as D
Example: If the serial No. is 77881.
D
= 77881
1
Note: Use six digits of the low rank when a serial No. is more than
seven digits.
3) Obtain D
and H
corresponding to D
2
1
Example: If D
D
= D
2
H
= FE
1
D
(Decimal)
D
1
000001 to 065535
D
1
065536 to 131071
D
1
131072 to 196607
D
1
4) Input H
to page: 8, address: 91. (Model code input)
1
Example: If H
Select page: 8, address: 91, set data: FE, and
press the PAUSE button.
5) Obtain the maximum decimal not exceeding D
3-3, and take this as D
Example: If D
D
= 12288
3
6) Obtain the hexadecimal corresponding to D
3, and take this as H
Example: If D
H
= 3000
3
7) Obtain the difference D
calculation, 0
D
4
D
= D
– D
4
2
3
Example: If D
D
= 12345 – 12288 = 57
4
8) Convert D
to hexadecimal, and take this as H
4
(Refer to "Hexadecimal-decimal conversion table" in "6-4.
Service Mode".)
Example: If D
H
= 39
4
9) Input the upper 2 digits of H
Example: If H
Select page: 8, address: 92, set data: 30, and
press the PAUSE button.
10) Input H
to page: 8, address: 93.
4
Example: If H
Select page: 8, address: 93, set data: 39, and
press the PAUSE button.
11) Select page: 0, address: 01, and set data: 00.
6-78
8
91, 92, 93
from Table 6-3-2.
1
is "77881".
1
– 65536 = 12345
1
H
(Hexadecimal)
1
(Decimal)
2
(Service model code)
FE
–65536
FE
–131072
FE
Table 6-3-2.
is "FE".
1
from Table 6-
2
.
3
is "12345".
2
from Table 6-3-
3
.
3
is "12288".
3
between D
and D
4
2
3
255)
is "12345" and D
is "12288".
2
3
.
4
is "57".
4
to page: 8, address: 92.
3
is "3000".
3
is "39".
4
.
1
. (Decimal

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvcam dsr-pdx10pDvcam rmt-811

Table of Contents