1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments (except for "66MHz/
54MHz Origin Oscillation Adjustment"), check that the specified
values of "VIDEO SYSTEM ADJUSTMENTS" are satisfied.
And check that the data of page: 0, address: 10 is "00". If not, set
data: 00 to this address.
Note: NTSC model: DSR-PDX10
PAL model: DSR-PDX10P
1. 66MHz/54MHz Origin Oscillation Adjustment
(VC-318 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin 6 of IC1202 (R1209) or
Pin wd of IC3404 on DB-016 board
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified Value
Pin 6 of IC1202 :
Note: The data of page: 0, address: 10 must be "00".
Adjusting method:
Order Page Address Data
1
0
01
01
2
F
10
3
F
10
4
0
01
00
R1209
IC1202
Fig. 6-1-9.
f=33000000 ± 165Hz (NTSC)
f=27000000 ± 135Hz (PAL)
Procedure
Set the data.
Change the data and set the
frequency (f) to the specified value.
Press PAUSE button.
Set the data.
16
1
17
64
32
19
33
48
VC-318 board
6-21
DSR-PDX10/PDX10P
DB-016 board
12
1
13
48
IC3404
24
37
25
36
Fig. 6-1-10.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvcam dsr-pdx10pDvcam rmt-811

Table of Contents