1-2-1.
INITIALIZATION OF A, D PAGE DATA
Note: The data of page: 0, address: 10 must be "00".
1. Initializing the A, D Page Data
Note1: If "Initializing the A, D Page Data" is performed, all data of the A
page and D page will be initialized. (It is impossible to initialize a
single page.)
Note2: If the A, D page data has been initialized, the following adjustments
need to be performed again.
1) Modification of A, D page data
2) Touch panel adjustment
Note3: The power supply voltage must be 6.0 ± 0.1Vdc.
Note4: NTSC model: DSR-PDX10
PAL model: DSR-PDX10P
Adjusting page
A
Adjusting Address
10 to FF
Adjusting page
D
Adjusting Address
10 to 7F
Initializing Method:
Order Page Address Data
1
0
01
01
2
0
10
00
3
7
03
4
7
00
28
5
7
01
28
6
7
02
7
2
00
29
8
2
01
29
9
Procedure
Set the data.
Set the data.
Set the following data.
08 (NTSC), 88 (PAL)
Set the data.
Set the data, and press PAUSE
button.
Check that the data changes to
"01"
Set the data.
Set the data, and press PAUSE
button.
Perform "Modification of A, D
Page Data".
2. Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
"Fixed data-2" address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of A, D Page data
Order Page Address Data
1
2
00
2
2
01
Note: If the following symptoms occur after completing of the
"Modification of A, D page data", check that the data of the "Fixed
data-2" addresses of A and D page are same as those of the same
model of the same destination.
1) The self-diagnosis code "E:20:00" on the LCD screen is displayed.
2) The power is shut off so that unit cannot operate.
6-11
DSR-PDX10/PDX10P
Procedure
29
Set the data.
29
Set the data, and press PAUSE
button.