1-2-2.
INITIALIZATION OF 8, C PAGE DATA
Note: The data of page: 0, address: 10 must be "00".
1. Initializing the 8, C Page Data
Note1: If "Initializing the 8, C Page Data" is performed, all data of the 8
page and C page will be initialized. (It is impossible to initialize a
single page.)
Note2: If the 8, C page data has been initialized, following adjustments
need to be performed again.
1) Modification of 8, C page data
2) Viewfinder system adjustments
3) LCD system adjustments
4) Servo and RF system adjustments
5) Serial No. input
6) Video system adjustments
Note3: The power supply voltage must be 6.0 ± 0.1Vdc.
Adjusting page
8
Adjusting Address
00 to A3
Adjusting page
C
Adjusting Address
10 to FF
Initializing Method:
Order Page Address Data
1
0
01
01
2
0
10
00
3
3
81
4
3
80
0C
5
3
80
6
2. Modification of 8, C Page Data
If the 8, C page data has been initialized, change the data of the
"Fixed data-2" address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C Page data
Order Page Address Data
1
2
00
29
2
2
01
29
Procedure
Set the data.
Set the data.
Check that the data is "00".
Set the data, and press PAUSE
button.
Check that the data changes to
"1C".
Perform "Modification of 8, C
Page Data".
Procedure
Set the data.
Set the data, and press PAUSE
button.
3. 8 Page Table
Note1: The data of page: 0, address: 10 must be "00".
Note2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, C
Page Data".)
Fixed data-2: Modified data. (Refer to "2. Modification of 8, C
Page Data").
Address
Address
Initial value
Initial value
00 to 21
22
23 to 2E
2F
30 to 3A
3B
3C to 49
4A
4B to 51
52
53 to 79
7A
7B
7C
7D
7E
7F
80
81
82
83
84 to 89
8A
8B
8C
08
8D
00
8E
46
8F
01
90
02
91
00
92
00
93
00
94 to A3
6-13
DSR-PDX10/PDX10P
Remark
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Serial No. input
Fixed data-1
Table. 6-1-4.