AT commands
Set IA to 0xFFFFFFFFFFFFFFFF to disable I/O line passing.
Set IA to 0xFFFF to allow any I/O packet addressed to this device (including broadcasts) to change the
outputs.
Parameter range
0 - 0xFFFF FFFF FFFF FFFF
Default
0xFFFFFFFFFFFFFFFF (I/O line passing disabled)

T0 (D0 Timeout)

This command applies to the XBee SX 868 RF Module.
Specifies how long pin D0 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0

T1 (D1 Output Timeout)

This command applies to the XBee SX 868 RF Module.
Specifies how long pin D1 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0

T2 (D2 Output Timeout)

This command applies to the XBee SX 868 RF Module.
Specifies how long pin D2 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0

T3 (D3 Output Timeout)

This command applies to the XBee SX 868 RF Module.
XBee® SX 868 RF Module User Guide
I/O line passing commands