AT commands

I/O line passing commands

Configure the device for I/O line passing. When enabled, incoming I/O sample data will affect the state
of analog and digital lines that are configured as output.

IA (I/O Input Address)

The source address of the device to which outputs are bound.
To disable I/O line passing, set all bytes to 0xFF.
To allow any I/O packet addressed to this device (including broadcasts) to change the outputs, set IA
to 0xFFFF.
Parameter range
0 - 0xFFFF FFFF FFFF FFFF
Default
0xFFFFFFFFFFFFFFFF (I/O line passing disabled)

IU (Send I/O Sample to Serial Port)

Indicates whether or not I/O samples should be sent to the serial port. 0 suppresses output; 1 allows
output (only if the device is in API mode).
Parameter range
0 - 1
Parameter
0
1
Default
1

T0 (D0 Timeout)

Specifies how long pin
reverts to configured value. If set to 0, there is no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0

T1 (D1 Output Timeout)

Specifies how long pin
reverts to configured value. If set to 0, there is no timeout.
Digi XBee3® DigiMesh 2.4 RF Module User Guide
Description
Disabled
Enabled
D0 (DIO0/ADC0/Commissioning Configuration)
D1 (DIO1/ADC1/TH_SPI_ATTN Configuration)
I/O line passing commands
holds a given value before it
holds a given value before it
155