Voltage input

9.5
ZS4800-2001
9.5.1
AX8620
ZS4800-2041
9.5.2
AX8640
Version: 1.1
Do not remove the bridge between R
Proper commissioning is only possible if the bridge between the
terminal points R
and R
Bint+
nal brake resistor can be connected.
Without this measure the AX8000 multi-axis servo system will be
shut down with an error message.
• X01 slot on AX8620 power supply modules
Terminal point
Connection
PE
Protective conductor
L3 / N
Phase L3 / N
L2
Phase L2
L1
Phase L1
Wire cross-section
Maximum 6 mm²
AWG 8
Mounting
Screws with tightening torque
0.5 Nm – 0.6 Nm / 4.4 lbf in – 5.3 lbf in
• X01 slot on AX8640 power supply modules
Terminal point
Connection
L3 / N
Phase L3
L2
Phase L2
L1
Phase L1
PE
Protective conductor
Wire cross-section
Maximum 16 mm²
AWG 6
Mounting
Screws with tightening torque
1.2 Nm – 1.5 Nm / 10.6 lbf in – 5.3 lbf in
AX8000
Electrical installation
and R
Bint+
B-
is not removed. Alternatively, an exter-
B-
───
67