Electrical installation
Block diagrams
9.2
AX8620
9.2.1
Number
1
2
3
4
5
6
7
8
9
58
───
Sample connection scenarios are presented below using schematic
connection diagrams for the power supply modules and axis mod-
ules.
9.2.1
Explanation
Connection socket for incoming EtherCAT cable
Connection socket for outgoing EtherCAT cable
Measuring and test contacts on the devices
Quick coupling of the AX8000 multi-axis servo system; AX bridge
Optional brake resistor
When using an optional brake resistor on the AX8000 multi-axis servo system, the
bridge of the 10-pin supply plug "X01" between R
Fuses F5 and F6 for optional brake resistor
If you add the optional brake resistor, the cable must be protected by the fuses F5
and F6.
Schematic contacts on the 10-pin supply plug "X01"
Power supply unit with 24 V
Optional mains choke
AX8000
and R
B-
supply voltage
DC
must be removed
Bint
Version: 1.1