Beckhoff AX8000 Series Operating Instructions Manual page 73

Multi-axis servo system
Hide thumbs Also See for AX8000 Series:
Table of Contents

Advertisement

AX82xx-0x10
Version: 1.1
A D-Sub slot is available in each case for the AX82xx-0x10 dual-
axis module:
• Left slot X11: assignment to the left axis channel 1
• Right connection X21: assignment to the right axis channel 2
Pin
EnDat 2.2
1
n.c.
2
GND
3
n.c.
4
---
5
Data; DX+
6
Us 11 V
7
n.c.
8
Clock; CLK+
9
n.c.
10
n.c.
11
n.c.
12
n.c.
13
Data; DX-
14
n.c.
15
Clock; CLK-
AX8000
Electrical installation
BiSS C
n.c.
GND
n.c.
5 V
  ± 10%
DC
Data+ / SLO+
---
DC
n.c.
CLK+ / MA+
n.c.
n.c.
n.c.
n.c.
Data- / SLO-
n.c.
CLK- / MA-
───