5.2

Technical data

5.2.1

Ambient and operating conditions

UL-listed!
If you wish to operate a component from the AX8000 multi-axis servo system in a US or
Canadian economic area that requires cULus approval, be sure to read section 3.3: "UL ap-
proval in the USA and Canada [} 10]".
Ambient / operating conditions
Ambient temperature during operation
Ambient temperature during transport
Ambient temperature during storage
Air humidity
Level of contamination
Corrosion protection
Operating altitude
Installation position
Ventilation
Protection class
Multi axis servo system AX8000
Permissible values
0 °C to +40 °C
up to +55 °C with power derating of 2.5 % / K
-25 °C to +70 °C
-25 °C to +55 °C
15% to 85%, non-condensing
2 according to EN 60204/EN 50178
Normally not required.
Under extreme operating conditions separate
measures must be agreed with the manufacturer.
Up to 1000 m above sea level without power
derating.
From 1000 m up to 2000 m with power derating →
1.5 % / 100 m.
Vertical
built-in temperature-controlled fan
IP 20 except the terminals (IP00)