Version numbers............................... 6 Scope of the documentation .......................... 6 Staff qualification............................... 7 Safety and instruction ............................ 9 Explanation of symbols ............................. 9 Beckhoff Services ............................ 11 For your safety.............................. 12 Safety pictograms ............................ 12 General safety instructions .......................... 13 Product overview............................... 15 Name plate..............................
Documentation notes Disclaimer Beckhoff products are subject to continuous further development. We reserve the right to revise the operating instructions at any time and without prior announcement. No claims for the modification of products that have already been supplied may be made on the basis of the data, diagrams and descriptions in these operating instruc- tions.
Product features Only the product properties specified in the current operating in- structions are valid. Further information given on the product pages of the Beckhoff homepage, in emails or in other publications is not authoritative. Scope of the documen- Apart from these operating instructions, the following documents are...
Trained specialists have received specific technical training and have specific technical knowledge and experience. Trained special- ists can: • apply relevant standards and directives • assess tasks that they have been assigned • recognize possible hazards • prepare and set up workplaces Version: 2.0 AX2090-ND80 ───...
Page 8
They are familiar with relevant standards and directives. Quali- fied electricians can: • independently recognize, avoid and eliminate sources of danger • implement specifications from the accident prevention regula- tions • assess the work environment • independently optimize and carry out their work ─── AX2090-ND80 Version: 2.0...
1.6.1 DANGER Failure to observe will result in serious or fatal injuries. WARNING Failure to observe may result in serious or fatal injuries. CAUTION Failure to observe may result in minor or moderate injuries. Version: 2.0 AX2090-ND80 ───...
Page 10
In the case of documentation on a monitor screen, use the zoom function to enlarge the QR code and reduce the distance. ─── AX2090-ND80 Version: 2.0...
Beckhoff and the worldwide partner companies offer comprehensive support and service. Support The Beckhoff Support offers technical advice on the use of individ- ual Beckhoff products and system planning. The employees support 1.7.1 you in the programming and commissioning of complex automation systems.
Safety pictograms On Beckhoff products you will find attached or lasered safety pic- tograms, which vary depending on the product. They serve to pro- tect people and to prevent damage to the products. Safety pic- tograms must not be removed and must be legible for the user.
Ground all conductive components according to the specifications in the chapters "Electrical Installation" and "Me- chanical Installation". Only use original packaging for further processing When shipping, transporting, storing and packing, use the original packaging or conductive materials. Version: 2.0 AX2090-ND80 ───...
Page 14
De-energize and switch off components before working on them 2.2.3 Check the functionality of all safety-relevant devices. Secure the working environment. Secure the machine or plant against being in- advertently started up. Observe the chapter: "Decommissioning" ─── AX2090-ND80 Version: 2.0...
Product overview Number Explanation Screw for PE ground connection Terminal block connections L1/L1´ L2/L2´ L3/L3´ Base plate for mounting Version: 2.0 AX2090-ND80 ───...
B and mains frequency; 50 ... 60 Hz Inductance Resistance Serial number European standard EN 61558 Back-up fuse UR certification with specification of the E-number Country of manufacture CE certification Mains choke Data Matrix Code with Beckhoff BTN ─── AX2090-ND80 Version: 2.0...
Mains choke Series AX8000 Not defined Execution 10 = AX8620-0000 for single-phase power supply with 10 A 20 = AX8620-0000 for three-phase power supply with 20 A 30 = AX8640-0000 for three-phase power supply with 40 A Version: 2.0 AX2090-ND80 ───...
IGBT switching processes of the AX8000 multi-axis servo sys- tem and smooth current peaks. UL and CSA marking The mains chokes from the AX2090-ND80-xxxx series are marked "UL Recognized Component" in accordance with applicable UL and CSA safety requirements. You may therefore use the mains chokes in products, plants or systems bearing the UL test mark.
Product overview Intended use The mains chokes from the AX2090-ND80-xxxx series may only be operated on an AX8620 power supply module on terminal X1 or on an AX8640 power supply module on terminal X02. Together with the AX86xx power supply modules on a multi-axis...
Temperatures above +40 °C and encapsulated installation can shorten the life of the mains chokes. Beckhoff products are designed for operation under certain environ- mental conditions, which vary according to the product. The follow- ing specifications must be observed for operation and environment in order to achieve the optimum service life of the products.
Technical data AX2090-ND80-0010 Electrical data AX2090-ND80-0010 Rated current [A Rated supply voltage [V 1 x 240 -25 % +10% Voltage drop [V Inductance [mH] 1.83 Inductance tolerance [%] ± 10 Test voltage 2500 Short-circuit voltage [UK] 4% at 400 V Connection technology Phase connection [mm²]...
Technical data AX2090-ND80-0020 Electrical data AX2090-ND80-0020 Rated current [A Rated supply voltage [V 3 x 400 -25 % +10% Voltage drop [V Inductance [mH] 1.47 Inductance tolerance [%] ± 10 Test voltage 4000 Short-circuit voltage [UK] 4% at 400 V Connection technology Phase connection [mm²]...
Technical data AX2090-ND80-0040 Electrical data AX2090-ND80-0040 Rated current [A Rated supply voltage [V 3 x 400 -25 % +10 % Voltage drop [V Inductance [mH] 0.47 Inductance tolerance [%] ± 10 Test voltage 4000 Short-circuit voltage [UK] 4% at 400 V Connection technology Phase connection [mm²]...
Please check that the delivery includes the following items: • AX2090-ND80-xxxx mains choke Packaging If the mains choke is dispatched in a collective order, instructions for handling are printed on the packaging of the collective order:...
• Use of the vendor's original packaging The table shows the maximum stacking height with which you can store and transport the mains chokes on a pallet in the original pack- aging: Mains choke type Stacking height [pieces] AX2090-ND80 ─── AX2090-ND80 Version: 2.0...
Use suitable means of transport and secure the mains choke against large mechanical stresses. Large mechanical stresses will damage the mains choke and indi- vidual components. All mains choke models from the AX2090-ND80-xxxx series can be transported without aids. Long-term storage Observe the maximum storage time Do not exceed a maximum storage time of five years.
Technical description Installation position The standard installation position of the mains choke is the upright mounting position. ─── AX2090-ND80 Version: 2.0...
EMC interference emissions. The minimum cross-sections of separate protective conductors can be found in EN 61439-1. ► Make the ground (PE) connection [1] ► Make the following connections [2]: • L1/L1´ • L2/L2´ • L3/L3´ Version: 2.0 AX2090-ND80 ───...
Electrical installation Cables Beckhoff offers pre-assembled cables for faster and flawless instal- lation of the motors. These cables are tested with regard to the ma- terial used, shielding and connection type. Perfect functioning and compliance with legal regulations, such as EMC and UL, are guar- anteed.
As a rule, no special maintenance and cleaning measures are fore- seen for mains chokes from the AX2090-ND80-xxxx series. A mains choke must be replaced in the event of malfunctions or faults.
Serious or even fatal injuries may result if this is ignored. Do not remove components from the products Only Beckhoff Automation GmbH & Co. KG is permitted to remove components. Contact Beckhoff Service if you have any questions.
The trans- 10.2.1 port costs are borne by the sender. Send the used devices with the note "For disposal" to: Beckhoff Automation GmbH & Co. KG Building "Service“ Stahlstraße 31 D-33415 Verl In addition, you have the option to contact a local certified specialist company for the disposal of used electrical and electronic appli- ances.
RoHS: EN 50581:2012 "Technical documentation for the assessment of electrical and elec- tronic products with respect to the restriction of hazardous sub- stances" Guidelines 2014/35/EU Low Voltage Directive 11.2 2011/65/EU RoHS Directive 2014/30/EU EMC Directive Version: 2.0 AX2090-ND80 ───...
The cURus logo can be found on the name plate. EU conformity Provision 11.4 Beckhoff Automation GmbH & Co KG will be pleased to provide you with EU declarations of conformity and manufacturer's declara- tions for all products on request. Send your request to: info@beckhoff.com ───...