Technical description

Dimensioning

7.5
DC link capacitance
7.5.1
42
───
Important information on the DC link capacitance, the total motor ca-
ble lengths and the dimensioning of the 24 V
be found below. Subsequently, there is a practical example.
Observe the maximum chargeable DC link capacitance
The maximum chargeable DC link capacitance must be considered
when designing the machine or plant:
• The capacities can be taken from the following table.
The power supply modules charge up the entire DC link when the
mains supply is first switched on.
DC link capacitance
• All figures in µF
Module
230 VAC
AX8620-0000
25000
AX8640-0000
40000
Maximum chargeable DC link capacitance at 400 V
The system includes:
•   1 x AX8640-0000 with 675 µF
• 10 x AX8206-0000 with 1350 µF
•   1 x AX8810-0000 with 1755 µF
That makes a total capacitance of 3870 µF.
The system is permissible, because a power supply module on the
400 V
supply network can charge up a capacitance of 13500 µF.
AC
AX8000
control voltage can
DC
400 VAC
480 VAC
8500
6000
13500
9500
AC
Version: 1.1