Axis module display
7.6.2
EtherCAT
Axis module
Version: 1.1
In the case of a two-channel axis module, the display is vertically di-
vided. The left column shows the symbols for channel A, the right
column shows the symbols for channel B. The EtherCAT symbol is
shown in the center.
Information on the meaning of the different symbols on the display
of the single-channel axis module is given below:
E = EtherCAT
Corresponds to the description for the power supply module:
See chapter "Power supply module display", [Page 45]
A = axis module
Axis symbol lights up green:
The axis is enabled and free from errors.
Axis symbol flashes green:
Fast blinking: The axis is disabled and is being initialized.
Slow flashing: The axis is disabled and free from errors.
Axis symbol lights up red:
The module is in EtherCAT INIT state.
Axis symbol flashes red:
Error.
Axis symbol flashes green-red:
The error reaction of the axis is active.
AX8000
Technical description
───
47