Disassembly

13.1
Version: 1.1
Disassembly may only be carried out by qualified and trained per-
sonnel.
Read the section Documentation notes.
When disposing of electronic waste, make sure that you dispose of
it in accordance with the regulations applicable in your country.
Read and follow the instructions for proper disposal.
WARNING
Avoid contact with DC link DC+ and DC-
Measure the voltage on the DC link test contacts DC+ und DC-.
Keep to the waiting times after disconnection from the supply net-
work:
• 30 minutes for AX8620 and AX8640
• 30 minutes for AX8108, AX8118 and AX8206
There is still a life-threatening voltage of > 875 V
tors after disconnection from the supply network. Serious or even
fatal injuries may result if this is ignored.
Do not remove components from the products
Only Beckhoff Automation GmbH & Co. KG is permitted to remove
components.
Contact Beckhoff Service if you have any questions.
Removal of the servo drive from the machine
• Remove cables and electrical connections
• Loosen and remove the servo drive fixing screws
• Transport the servo drive to the workplace or put it into storage