Pos : 162 /Anleitungen/El ektr oni k/FU und Starter/2. M ontage und Installation/Elektrischer Ans chl uss/SK 1xxE, SK 2xxE, SK xxxE-FDS/Steuer teil/D etails Steuer klemmen [SK 2xxE] @ 1\mod_1342598807861_14638.doc x @ 33652 @ 455 @ 1
Control terminal details
Labeling, function
SH:
Function: Safe stop
AS1+/-:
Integrated AS interface
24 V:
24 V DC control voltage
10 V REF:
10 V DC reference voltage for AIN
AGND:
Reference potential for analog signals
GND:
Reference potential for digital signals
DIN:
Digital input
Connections depending on the variable frequency drive type
Detailed information regarding functional safety (safe stop) can be found in supplementary manual
Sizes 1 ... 3
SK 200E
SK 210E
SK 220E
SH
24 V (output)
AIN1+
AIN2+
AGND
DIN1
DIN2
DIN3
DIN4
24 V SS
DIN4
GND
0 V SS
GND
DOUT1
GND
SYS H
SYS L
10 V REF
DOUT2
GND
TF+
TF-
* when using the AS interface, terminal 44 provides an output voltage (26.5 V DC ... 31.6 V DC, max. 60 mA). In this case, no