NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
Pos : 465 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P400- P499/Parameter P480 – Funktion Bus I/O In Bits [SK 1x0E, SK 2xxE] @ 2\mod_1346931810637_14638.doc x @ 42908 @ @ 1
P480
[-01]
Function BusIO In Bits
...
(Function Bus I/O In Bits)
[-12]
0 ... 80
The Bus I/O In Bits are perceived as digital inputs. They can be set to the same functions (P420).
{ [-01] = 01 }
With devices with an integrated AS interface, the I/O bits can be used by the interface itself (bit 0
... 3) or in combination with I/O extensions (SK xU4-IOE) (bits 4 ... 7 and bits 0 ... 3). The priority
{ [-02] = 02 }
in AS-i devices is AS-i. In this case, BUS IO BITs 1 ... 4 cannot be used by the 2nd IO extension.
{ [-03] = 05 }
[-01] = Bus/AS-i Dig In1
{ [-04] = 12 }
[-02] = Bus/AS-i Dig In2
{ [-05...-12] = 00 }
[-03] = Bus/AS-i Dig In3
[-04] = Bus/AS-i Dig In4
[-05] = Bus/IOE Dig In1
[-06] = Bus/IOE Dig In2
[-07] = Bus/IOE Dig In3
[-08] = Bus/IOE Dig In4
[-09] = Flag 1
[-10] = Flag 2
[-11] = Bit 8 BUS controlword
[-12] = Bit 9 BUS controlword
The possible functions for the bus In bits can be found in the table of functions for the digital
inputs in parameter (P420). Functions {14} "Remote control" and {29} "Enable Setpoint Box" are
not possible.
1) The flag function is only possible with control via control terminals.
Pos : 466 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P400- P499/Parameter P481 – Funktion Bus I/O Out Bi ts [SK 1x0E, SK 2xxE] @ 2\mod_1346931811511_14638.doc x @ 42932 @ @ 1
P481
[-01]
Funct. BusIO Out Bits
...
(Function Bus I/O Out Bits)
[-10]
0 ... 40
The bus I/O Out bits are perceived as multi-function relay outputs. They can be set to the same
functions (P434).
{ [-01] = 18 }
With devices with in integrated AS interface, the I/O bits can be used by the interface itself (bit 0
{ [-02] = 08 }
... 3) or in combination with I/O extensions (SK xU4-IOE) (bits 4 ... 5 and flags 1 ... 2).
{ [-03] = 30 }
[-01] = Bus / AS-i Dig Out1
{ [-04] = 31 }
[-02] = Bus / AS-i Dig Out2
{ [-05...-10] = 00 }
[-03] = Bus / AS-i Dig Out3
[-04] = Bus / AS-i Dig Out4
[-05] = Bus / IOE Dig Out1
[-06] = Bus / IOE Dig Out2
[-07] = Bus / 2nd IOE Dig Out1
[-08] = Bus / 2nd IOE Dig Out2
[-09] = BUS statusword Bit 10
[-10] = BUS statusword Bit 13
The possible functions for the Bus Out Bits can be found in the table of functions for the digital
outputs (P434).
1) The flag function is only possible with control via control terminals.
Pos : 467 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265496 @ @ 1
184
(Bus IO In Bit 0 + AS-i 1 or DI 1 of the second SK xU4-IOE (DigIn 09))
(Bus IO In Bit 1 + AS-i 2 or DI 2 of the second SK xU4-IOE (DigIn 10))
(Bus IO In Bit 2 + AS-i 3 or DI 3 of the second SK xU4-IOE (DigIn 11))
(Bus IO In Bit 3 + AS-i 4 or DI 4 of the second SK xU4-IOE (DigIn 12))
(Bus IO In Bit 4 + DI 1 of the first SK xU4-IOE (DigIn 05))
(Bus IO In Bit 5 + DI 2 of the first SK xU4-IOE (DigIn 06))
(Bus IO In Bit 6 + DI 3 of the first SK xU4-IOE (DigIn 07))
(Bus IO In Bit 7 + DI 4 of the first SK xU4-IOE (DigIn 08))
1)
1)
(Bus IO Out Bit 0 + AS-i 1)
(Bus IO Out Bit 1 + AS-i 2)
(Bus IO Out Bit 2 + AS-i 3)
(Bus IO Out Bit 3 + AS-i 4)
(Bus IO Out Bit 4 + DO 1 of the first SK xU4-IOE (DigOut 02))
(Bus IO Out Bit 5 + DO 2 of the first SK xU4-IOE (DigOut 03))
(Flag 1
(Flag 2
1)
+ DO 1 of the second SK xU4-IOE (DigOut 04))
1)
+ DO 2 of the second SK xU4-IOE (DigOut 05))
BU 0200 en-US-3118