NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
Pos : 36.8 /Anl eitungen/Elektroni k/FU und Starter/1. Allgemei nes/Sicherheits- und Installati onshi nweis e und Warn- Gefahr enhinweis e/neu/Sicher heits- und Installationshi nweise - Ei nzel punkte/4_b. Aufstellung und M ontage (Sic her hei tshi nweise) @ 19\mod_1508741535965_14638.doc x @ 2368407 @ @ 1
Installation and assembly
Installation and cooling of the device must be carried out according to regulations in the corresponding
documentation. Comply with the permissible mechanical and climatic ambient conditions (see
Technical Data in the device manual).
Protect the device against inadmissible loads. In particular, prevent component deformation and/or
modification of insulation distances. Avoid touching electronic components and contacts.
The device and its optional modules contain electrostatically sensitive components which can be
easily damaged by incorrect handling. Electrical components must not be mechanically damaged or
destroyed.
Pos : 36.9 /Anl eitungen/Elektroni k/FU und Starter/1. Allgemei nes/Sicherheits- und Installati onshi nweis e und Warn- Gefahr enhinweis e/neu/Sicher heits- und Installationshi nweise - Ei nzel punkte/4_c. El ektrisc her Ansc hlus s (Sic herheits hinweise) [dez entral e Geräte] @ 19\mod_1508742394542_14638.doc x @ 2368512 @ @ 1
Electrical connection
Ensure that the device and the motor are specified for the correct supply voltage.
Installation, maintenance and repair work must not be carried out unless the device has been de-
energized and at least 5 minutes have elapsed since line power has been disconnected! (Due to
charged capacitors, the device may continue to carry hazardous voltages for up to 5 minutes after line
power has been disconnected). Before starting work it is essential to check by measurement that all
contacts of the power plug connectors or terminals are de-energized.
Establish the electrical installation as per applicable regulations (e.g. cable cross-section, fuses,
protective conductor connection). Please refer to the documentation or manual for the device for
further instructions.
Information regarding EMC-compliant installation such as shielding, grounding, setup of filters and
routing of cables can be found in the documentation for the device and in Technical Information
TI
80-0011. CE-marked devices must also comply with these instructions. The manufacturer of the
system or machine is responsible for compliance with the limit values specified in EMC regulations.
In case of a fault, insufficient grounding may cause an electric shock with possibly fatal consequences
if the device is touched.
The device may only be operated with effective ground connections which comply with local
regulations for large leakage currents (> 3.5 mA). Please refer to Technical Information
TI 80-0019
for
detailed information regarding connections and operating conditions.
The device's voltage supply may start up the device directly or indirectly, or touching electrically
conducting components may cause an electric shock with possible fatal consequences.
Disconnect all poles of all power connections (e.g. power supply) at all times.
Pos : 36.10 /Anleitungen/El ektr oni k/FU und Starter/1. Allgemei nes /Sic herheits- und Ins tall ations hinweis e und Warn- Gefahrenhinweise/neu/Sic herheits- und Installati ons hi nweis e - Einz el punkte/4_d. Ei nrichtung, F ehlers uche und Inbetriebnahme (Sic her hei tshi nweise) @ 19\mod_1508747028856_14638.doc x @ 2368837 @ @ 1
Setup, troubleshooting and commissioning
Comply with applicable national accident prevention regulations when working on live devices (e.g.
BGV A3, formerly VBG 4).
The device's voltage supply may start up the device directly or indirectly, or touching electrically
conducting components may cause an electric shock with possible fatal consequences.
Parameterize and configure the devices in such a way that does not cause any hazards.
Under certain setting conditions the device or the motor connected to it may start automatically when
line power is switched on. A machine that it drives (press, chain hoist, roller, fan, etc.) may then make
an unexpected movement. This may cause various injuries, including to third parties.
Before switching on line power, secure the danger area by warning and removing all persons from the
danger area.
24