Pos : 599 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P734 – Strom Phas e W @ 0\mod_1328173871579_14638.doc x @ 15138 @ @ 1
Phase W current
P734
(W phase current)
0.0 ... 999.9 A
Displays the actual W phase current.
NOTE:
This value can deviate somewhat from the value in P719, due to the measurement procedure
used, even with symmetrical output currents.
Pos : 600 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P735 – Drehz ahl Dr ehg eber [SK 2xxE, SK 2xxE-FDS] @ 2\mod_1347348492128_14638.doc x @ 44460 @ @ 1
Speed encoder
P735
(encoder speed)
-9999 ... 9999 rpm
Displays the actual rotation speed supplied by the incremental encoder. For this, P301 must be
correctly set.
Pos : 601 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P736 – Z wisc henkreis spannung @ 0\mod_1328174969216_14638.doc x @ 15141 @ @ 1
Dc. link voltage
P736
(DC link voltage)
0 ... 1000 V DC
Displays the actual DC link voltage.
Pos : 602 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P736 – Z wisc henkreis spannung _Ergänz ung Anzeige klei ner Wert bei 24V_Geräten [SK 2xxE] @ 5\mod_1397202429585_14638.doc x @ 126260 @ @ 1
In devices with a separate 24 V supply, a small, non-typical value is displayed if no line voltage
is present (e.g.: with 1~ 230 V devices: P736 ≈ 4 V). This value results from internal measuring
and testing routines, and is dependent upon measuring errors, offsets and signal noise, for
example.
Pos : 603 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P737 – Aktuelle Ausl astung Brems wi ders tand @ 0\mod_1328175007763_14638.doc x @ 15142 @ @ 1
Usage rate brakeres.
P737
(present braking resistor load)
0 ... 1000 %
This parameter provides information about the actual degree of modulation of the brake chopper
or the current utilization of the braking resistor in generator mode.
If parameters P556 and P557 are correctly set, the utilization related to P557, the resistor power,
is displayed.
If only P556 is correctly set (P557=0), the degree of modulation of the brake chopper is displayed.
Here, 100 means that the braking resistor is fully switched. On the other hand, 0 means that the
brake chopper is not active at present.
If P556 = 0 and P557 = 0, this parameter also provides information about the degree of
modulation of the brake chopper in the VFD.
Pos : 604 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P738 – Aktuelle Ausl astung M otor [SK 1x0E, SK 2xxE, SK 2xxE-FDS] @ 2\mod_1346932207014_14638.doc x @ 43580 @ @ 1
P738
Usage rate motor
[-01]
[-02]
(present motor load)
0 ... 1000 %
Shows the actual motor load. Basis for calculation are the motor data P203. The actually recorded
current is related to the nominal motor current.
[-01] = related to I
[-02] = related I
Pos : 605 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265496 @ @ 1
BU 0200 en-US-3118
Information
(P203) of the motor
N
2
t control, "in relation to I
Display of untypical value
t monitoring" (P535)
2
5 Parameter
S
S
215

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents