NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
IP66 version:
The IP66 version is a modified option of the IP55 version. Both installation types (motor-integrated,
close to the motor) are also available for this version. The modules available to the IP66 design
(connection units, technology units and customer units) have the same functionalities as the
corresponding IP55 design modules.
Pos : 67 /Anl eitungen/Elektroni k/FU und Starter/1. Allgemei nes/Aus führung i n der Sc hutzart IP55 / IP66_Ergänz ung _IP66 [SK 2xxE] @ 6\mod_1430736640998_14638.doc x @ 214921 @ @ 1
Information
The modules for the IP66 version are identified by an additional "-C" in the model code and were modified with
the following special measures:
Impregnated PCBs,
Powder coating RAL 9006 (white aluminum) for housing,
Modified blank screw caps (UV-resistant),
Diaphragm valve for pressure compensation in the event of temperature changes,
Low-pressure test.
– A free M12 screw connection is required for low-pressure testing. A diaphragm valve is inserted here after
successful testing. This screw connection is therefore no longer available for the cable inlet.
If the variable frequency drive needs to be retrofitted, i.e. the drive unit (inverter pre-attached to motor)
is not entirely purchased from NORD, the diaphragm valve is supplied in the accessories kit with the
variable frequency drive. The valve must be professionally installed on site by the system installer
(note: the valve must be installed in a location that is as high as possible in order to avoid contact with
accumulated moisture, e.g. standing water due to condensation).
Pos : 68 /Anl eitungen/Elektroni k/FU und Starter/1. Allgemei nes/Aus führung i n der Sc hutzart IP55 / IP66_Ergänz ung _IP66_BG 4 [SK 2xxE] @ 6\mod_1430734064819_14638.doc x @ 214889 @ @ 1
Information
Variable Frequency Drives, size 4, could also be delivered up to week of manufacture 38/2012 (up to ID No.:
38M...) as "coated" versions "-C" but they only comply with IP55 because of the integrated fan. From ID No.:
39M.... these devices are also compliant with IP66.
"SK 2xxE-...-C" devices with output of 5.5 kW and 7.5 kW (230 V), and 11 kW and 15 kW (400 V) from ID No.:
28M... compliant with IP66.
Pos : 70 /Anl eitungen/Elektroni k/FU und Starter/2. M ontage und Ins tall ati on/M ontage/M ontag e und Ins tall ation (Ü bers chrift) [SK 1xxE, SK 2xxE, SK xxxE-FD S] @ 0\mod_1325859530370_14638.doc x @ 14817 @ 1 @ 1
36
IP66 special measures
"SK 2xxE-...-C" devices, size 4