Pos : 570 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P709 – Spannung Analog eingang [SK 2xxE] @ 2\mod_1346932205173_14638.doc x @ 43508 @ @ 1
P709
[-01]
Analog input voltage
...
(analog input voltage)
[-09]
-100 ... 100 %
Displays the measured analog input value.
SK 2x0E
[-01] =
[-02] =
SK 2xxE
[-03] =
[-04] =
[-05] =
SK 2xxE, size 1 – 3
[-06] =
[-07] =
SK 2xxE
[-08] =
[-09] =
Pos : 571 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P710 – Spannung Analog ausg ang [SK 1x0E, SK 2xxE, SK 2xxE-FD S] @ 2\mod_1346932205766_14638.doc x @ 43532 @ @ 1
P710
Analog output volta.
[-01]
[-02]
(analog output voltage)
0.0 ... 10.0 V
Displays the delivered value of analog output.
[-01] =
[-02] =
Pos : 572 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265496 @ @ 1
BU 0200 en-US-3118
Analog input 1, value of analog input
1 integrated in the VFD.
Analog input 2, value of analog input
2 integrated in the VFD.
Ext. Analog in 1, AIN 1 of the first SK xU4-IOE I/O extension
Ext. Analog in 2, AIN2 of the first SK xU4-IOE I/O extension
Setpoint module, SK SSX-3A, see
Analog function
dig..
2, analog
function of VFD digital input 2
Analog function
dig..
3, analog
function of VFD digital input 3
Ext. Al 1 2. IOE, "External analog input 1 2nd IOE", AIN1 of the second I/O extension
(SK xU4-IOE) (= analog input 3)
Ext. Al 2 2. IOE, "External analog input 2 2nd IOE", AIN2 of the second I/O extension
(SK xU4-IOE) (= analog input 4)
IOE-1, AOUT of the first I/O extension (SK xU4-IOE)
IOE-2, AOUT of the second I/O extension (SK xU4-IOE)
SK 2x5E
[-01] =
Potentiometer 1, internal
potentiometer P1 in the VFD (chapter
4.3.2), for setting the maximum
frequency, minimum frequency and
ramp time
[-02] =
Potentiometer 2, same as
potentiometer 1
BU0040
SK 2x0E, size 4
[-06] =
Potentiometer 1, internal
potentiometer P1 in the VFD (chapter
4.3.2), for setting the maximum
frequency, minimum frequency and
ramp time
[-07] =
Potentiometer 2, same as
potentiometer 1