VISION TOUCH WELLNESS
CHAPTER 11: OPERATION
Set parameter mOd = 0 to configure the control in "Sauna secca" (dry sauna) mode (or
"sauna Finlandese" [Finnish sauna]). In this case a temperature probe must be configured
and connected to the controller. Environmental humidity probes do not need to be
connected. The hot function is activated below the set temperature - dtC and remains on
until the set temperature is reached.
Set parameter mOd = 1 to configure the control in "Sauna con umidità" (Sauna with
humidity) mode (or Biosauna). In this case a temperature probe and an environmental
humidity probe must be configured and connected to the controller. The temperature and
environmental humidity setpoints can be set independently. The VISION TOUCH control
independently controls the conformity of the set values in accordance with European
Standard EN 60335-2-53:2012: in the case of violation the humidity setpoint is saturated
according to the chart below.
Note. If the ambient temperature is greater than 70°C, the humidifying call is disabled.
USER AND MAINTENANCE MANUAL
Pag. 88
WELLNESS CONFIGURATION: SAUNA
WELLNESS CONFIGURATION: WET SAUNA