8.3.1
"Process adjustment" allows setting the differentials and the temperature and humidity
neutral area of the WELLNESS.
The "Process adjustment" menu can be accessed from the main Configuration page
("Parameters" Button). The display of this item can be set in the "Password" sub-menu =>
"Configure user level menu" and by selecting the "Process adjustment" item (installer login
required).
Process regulation
VARIABLES
HOT temperature differential with reference to main SET-
POINT. It is expressed in absolute value and it defines the
dtC
temperature hysteresis for HOT referred to the temperature
SET-POINT.
HUMIDIFICATION differential with reference to humidity
SET-POINT. It is expressed in absolute value and it defines
dUU
the humidification hysteresis referred to the humidity SET-
POINT.
Operating time following a manual or scheduled switch-on
tf
(no programmable thermostat)
USER AND MAINTENANCE MANUAL
Pag. 43
Process adjustment
MEANING
VISION TOUCH WELLNESS
VALUES
0,2 ÷ 10,0 °C
1 ÷ 10 rH%
00:01 ÷ tFm
hours
Rel 01-19
DEFAULT
2,0 °C
5 rH%
1:00
hours