2.1. Description
The air filtering device serves to filter air and to set its pressure before it is distributed into the pneumatic
circuit of the bar feed system.
The air must be furnished at a maximum pressure of 6 bar, and whenever possible, clean and dry.
2.2. Layout of the elements
Designation
Description
A
Pressure regulator
B
Pressure gauge with pressure switch
C
Inlet
D
Regulated pressure outlet
E
Decanter
F
Automatic purging
2.3. Connection
The pneumatic connection (C) is located behind the control cabinet.
For the pneumatic connections of the bar feed system, the customer must provide a hose (B) with an
inside diameter of 1/2" (12.7 mm). For USA, 3/8" (9.5mm).
Provide an air hose long enough to allow the complete travel (600 mm) of the retraction system.
When the hose is connected, it should not lie on the
ground because it could become damaged.
1.
Place clamp (A) around hose (B).
2.
Insert fitting (C) into hose.
3.
Tighten the flange (A) to make it airtight.