Drum Unit Replacement - continued
Attach the new Drum
4
5
Unit to the
Developer Assembly
Drum Unit
Developer
Assembly
042
Attach the new Drum Unit to the
Holding the Developer Assem-
Developer Assembly. Position
bly by the green handles, align
the new Drum Unit with the
the three shafts on the Devel-
green drum surface facing the
oper Assembly sides with the
black toner roller on the Devel-
slots in the machine frame.
oper Assembly.
32
Install the Developer
6
Press Down on the
Assembly with Drum
Drum Unit
Unit
Developer
Assembly
043
Press firmly down on the green
squares on the Drum Unit until
the Drum Unit clicks into place.
Replacing the Ozone Filter
The Ozone Filter should be re-
placed every time the Drum Unit
is replaced.
Drum Unit
A new Ozone Filter has been
provided with the Drum Kit.
Make sure the Ozone Filter is
replaced.
044
7
Replace the Ozone
Filter
Ozone Filter
069
Remove the Ozone Filter from
the inside of the machine.
Then, place the new Ozone Fil-
ter into the machine.