FUNCTIONING
Modifying attachment flow rate settings
1. Select parameter (b) in the ATT - 2-way Attachment oil flow
rate setting menu and press F6.
2. In the oil flow rate setting screen accessible from the ATT -
2-way Attachment selection menu, select one of the two
values set for oil flow rate and press F6.
q The default oil flow rate values are both set at 130
litres/min, as shown to the right.
The oil flow rate currently set for ATT mode is
h i g hl i g h te d b y ATT/ P o r AT T/ E i n fr on t of th e
corresponding parameter.
q "No 2-Way Attachment" cannot be selected
From the ATT - 2-way Attachment selection menu, the
following operations are possible using function keys F3 to F6.
q F3: Select next entry (1 row down).
q F4: Select previous entry (1 row up).
q F5: Return to previous screen.
q F6: Display settings screen for selected parameter.