Komatsu PC118MR-8 Operation And Maintenance Manual page 131

Hydraulic
Table of Contents

Advertisement

FUNCTIONING
4. The monitor displays the ATT - 2-way Attachment selection
menu.
q ATT - 2-way Attachment selection menu Selecting this
parameter (a), the oil flow rate for ATT mode may be
selected from the two set values.
q ATT - 2-way Attachment oil flow rate setting menu
Selecting this parameter (b), the oil flow rate set for
ATT mode may be modified.
From the ATT - 2-way Attachment selection menu, the
following operations are possible using function keys F3 to F6.
q F3: Select next entry (1 row down).
q F4: Select previous entry (1 row up).
q F5: Return to previous screen.
q F6: Display settings screen for selected parameter.
Modifying "attachment" settings selection
1. Select parameter (a) in the attachment settings menu and
press F6.
WEAM014802
INSTRUMENTS AND CONTROLS
3-47

Hide quick links: