Festo CPA VI Series Manual page 91

Valve terminal with cpa pneumatics
Hide thumbs Also See for CPA VI Series:
Table of Contents

Advertisement

5. Maintenance and conversion
CPA variants
Tab. 5/2:
Removing the CPA valve terminal fitted onto a wall
Festo P.BE-CPA-EN en 0207c
Loosening the CPA valve terminal fitted onto a wall
1. Prevent the hanging CPA valve terminal from falling down
before you loosen it from the fastening surface.
2. Loosen the fastening screws as shown in the following
diagram.
Fastening
CPA valve terminal:
– 2 M6 screws on both the left and right-hand
end plates.
CPA terminal with CPX terminal:
– One screw on the left-hand end plate and 2
screws on the right-hand end plate of the CPA
valve terminal.
– 2 screws on the CPX pneumatic interface
– 2 screws on the left-hand end plate of the CPX
terminal.
3. Remove the CPA valve terminal from the fastening
surface.