5. Maintenance and conversion
Festo P.BE-CPA-EN en 0207c
Fig. 5/9: Fitting the electrical sub-base
5. Place the end plate on the tie rods and screw the tie rod
screws a few turns into the tie rods.
6. Align the CPV valve terminal on a flat surface so that the
components are not offset.
7. Tighten the screws of the tie rods in two stages as follows:
Stage
1
2
Tab. 5/3:
Tightening torques of the tie rods
CPA10
CPA14
0.5 Nm
0.5 Nm
1.5 Nm
2 Nm