4. Commissioning
External
Pressure
auxiliary pilot
increase in
air
complete
supply
Branched after the
slow
safety start-up
valve
Branched in front
slow
of the safety
start-up valve
Tab. 4/3:
Effects of slow start-up pressurization
Carrying out the test
Festo P.BE-CPA-EN en 0207c
The table below shows the effects of slow start-up pressuriza-
tion when there are electric signals.
Pressure
increase in the
auxiliary pilot
air (12/14)
slow
fast
Proceed as follows:
1. Switch on the compressed air supply.
2. Check the functioning and operation of each individual
valve-cylinder combination by actuating the manual override
as shown in the following diagrams.
Please note
Incorrect actuation of the non-locking manual override can
lead to malfunctioning or damage to the manual override.
Use a blunt pencil for actuating the non-locking manual
override.
Actuate the manual override only with max. 30 N.
3. In the case of the CPA valve terminal with locking manual
override: After testing the valves, make sure that all man-
ual override actuations are in their basic positions.
4. Switch off the compressed air supply after checking the
valves.
Time point
Movement of
when a valve
the cylinder
switches
after pressure
fast
increase with (1)
before pressure
slow
increase with (1)
4-11