5. Maintenance and conversion
5-18
8. On sub-bases with components removed make sure that
the seals are correctly seated on the sub-base. They must
lie correctly in the appropriate seal grooves.
9. Place the removed components onto the appropriate sub-
bases again and tighten them slightly.
10. Tighten the fastening screws of all the components on the
sub-bases again as follows:
CPA10: 0.25 Nm (+ 0.05 Nm)
CPA14: 0.3 Nm (± 0.05 Nm)
11. If applicable, place the missing pin-type inserts in the
sub-bases (see chapter 3 "Installation, connecting the
supply, exhaust and work tubing").
12. Fit the CPA valve terminals onto their fastening surface
(see chapter 2 "Fitting," "Fitting onto a wall" or "Fitting
onto a hat rail").
13. Then fit the pneumatic and electrical connections
(see chapter 3 "Installation, connecting the CPA valve
terminal").
Festo P.BE-CPA-EN en 0207c