Festo CPA VI Series Manual page 113

Valve terminal with cpa pneumatics
Hide thumbs Also See for CPA VI Series:
Table of Contents

Advertisement

5. Maintenance and conversion
Number
Starting basis: valve terminals with
)
*
an even number of valve locations
- 1
2 basis tie rods and
2 long tie rod screws
- 2
2 basis tie rods
- 3
2 basis tie rods and
2 long tie rod screws
> - 3
2 basis tie rods if necessary
2 long tie rod screws
)
*
Number of valve locations to be removed
Tab. 5/8:
Adapting the tie rod length
Festo P.BE-CPA-EN en 0207c
The table below lists the tie rod components which you will
require for adapting the tie rod length.
Starting basis: valve terminals with
an odd number of valve locations
2 short tie rod screws
2 basis tie rods
2 basis tie rods
2 short tie rod screws
2 basis tie rods if necessary
2 short tie rod screws
5-29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cpa10viCpa14viCpa series

Table of Contents