Festo CPA VI Series Manual page 80

Valve terminal with cpa pneumatics
Hide thumbs Also See for CPA VI Series:
Table of Contents

Advertisement

4. Commissioning
Actuating the manual override with stop (locking)
CPA valve terminal
CPA valve terminal
with MP, CP, AS-In-
with IC connection
terface connection
or CPX terminal
Tab. 4/5:
Locking actuation of the manual override
4-14
Operation
CPA valve terminal with MP, CP,
AS-Interface connection or CPX
terminal:
Press down the plunger of the
manual override as far as
possible.
CPA valve terminal with
IC connection:
Press down the plunger of the
manual override until the valve
switches. Then turn the
plunger in a clockwise
direction as far as possible.
Leave the plunger in the lower
position.
CPA valve terminal with MP, CP,
AS-Interface connection or CPX
terminal:
Press the plunger of the
manual override into the inner
position as far as possible.
CPA valve terminal with
IC connection:
Turn the plunger in an anti-
clockwise direction as far as
possible. Then release the
plunger.
Reaction of the
valve
The valve:
– moves to the
switching
position
– remains in the
switch position
– returns to basic
position
(not in the case
of double-sole-
noid valve
type J)
Festo P.BE-CPA-EN en 0207c