3. Installation
3-22
Use the ready-to-use connector socket KMYZ-7-24-...-LED
from Festo for connecting the valve solenoid coils. The hold-
ing current reduction for the valve solenoid coil and an LED
are incorporated in the transparent plug of this connector
socket. The LED indicates the switching status of the valve
solenoid coils.
Please note
If the CPA valve terminal with IC connection is used at
maximum operating temperature and 100 % switch-on
duration, it must be operated wth current reduction. Use
here the connector socket KMYZ-7-24-...-LED.
Connect the valve solenoid coils as follows:
1. Insert the socket onto the terminal lugs of the appropriate
pilot solenoid or intermediate plug. The socket can be
fitted turned 180°. Make sure that the centring bolt be-
tween the terminal lugs grips into the hole in the socket
(see diagram).
2. Screw the socket together with the locking screw with
0.2 Nm.