3. Installation
3-16
2. Check that the seal of the pin-type is greased. If necess-
ary, grease the seal with Festo F2 grease.
3. Press the pin type inserts into the holes in the sub-base.
4. Make sure that the pin-type inserts are seated as far as
possible in the holes. Measure here the distance between
the connecting level and the locking ring of the pin-type
inserts (see diagram).
1
5.5 mm (CPA10) or 6.5 mm (CPA14)
Fig. 3/6: Checking the pin-type fitting
1
Festo P.BE-CPA-EN en 0207c