VIA! Touch Panel Connections

The S128P is designed to work flawlessly with ELAN VIA! Touch Panels. VIA! Touch Panels require ELAN 16 Volt
DC power supplies. Use the PWR10 16V/10A power supply to power up to ten VIA! Touch Panels. Use the PWR4
16V/4A power supply to power up to 4 VIA! Touch Panels. Use the PWR1 16V/1.5A power supply to power a single
touch panel.
When using a VIA! Valet 100EM Tabletop/Under-Cabinet Color Touch Panel, a PVIA1 Valet Wall Plate must be used.
One PVIA Wall Plate is included with each VIA! Valet. The installer has the option of using the included PVIA1 power
supply, or one of the other 16V power supplies to provide power to the Valet.
VIA! Touch Panels punch-down to the rear of the SPP at two locations, depending on system configuration. These
locations are labelled "ZXA 16V VIA!/OLÉ" and "ZXB 16V/12V VIA!/OLÉ" where "X" corresponds to the zone that the
touch panel(s) will control. Two touch panels can connect to each punch-down location for each zone. If using more
than 2 touch panels per location, make connections off of the SPP and use jumper wires to punch-down to the cor-
rect location. Figure 3-4 shows the correct wiring for one touch panel in Zone 1 connected to the "A" location and
utilizing 16VDC power from the PWR1, PWR4, or PWR10 power supply connected to the front of the SPP.
SPP to VIA! Touch Panel
N/C
IR
485-
485+
G
16V
G
16V
SPP to PVIA1VALET (Using 16 VDC from SPP)
N/C
IR
485-
485+
G
16V
G
16V
SPP to PVIA1VALET (Using 16 VDC from PVIA1)
N/C
IR
485-
485+
G
16V
G
16V
© ELAN Home Systems 2009 • All rights reserved.
S128P.indd 27
Blue
White/Blue
Orange
White/Orange
Cat-5
Green
White/Green
Brown
White/Brown
Blue
White/Blue
Orange
White/Orange
Cat-5
Green
White/Green
Brown
White/Brown
Blue
White/Blue
Orange
White/Orange
Cat-5
Gr een
X
White/Gr een
Br ow n
X
White/B ro wn
When connecting a PVIA1 Valet
Wall Plate to the SPP, use either the
included PVIA1 power supply connected
to the PVIA1 Wall Plate, or a PWR10,
PWR4 or PWR1 power supply connected
to the SPP.
DO NOT USE BOTH POWER SUPPLIES!
Figure 3-3: VIA! Touch Panel Connections
Butt splice
or equivalent
Blue
Blue
White/Blue
White/Blue (IR)
Orange
Orange (485-)
White/Orange
White/Orange (485+)
Green
Green (GND)
White/Green
White/Green (+16V)
Brown
Brown (GND)
White/Brown
White/Brown (+16V)
PVIA-1
nc
nc
SIR
nc
Z485-
nc
nc
Z485+
nc
Blue
ST/SNS
Blue
White/Blue
IR
White/Blue
Orange
V485-
Orange
White/Orange
V485+
White/Orange
Green
GND
Green
White/Green
+16V
White/Green
Brown
GND
Brown
White/Brown
+16V
White/Brown
PVIA-1
n c
n c
SIR
n c
n c
Z485-
n c
Z485+
n c
Blue
ST/SN S
Blue
White/Blue
IR
White/Blue
Orange
V485-
Orange
White/Orange
V485+
White/Orange
Gr een
GND
Gr een
X
White/Gr een
+16V
White/Gr een
Br ow n
GND
Br ow n
X
White/B ro wn
+16V
White/B ro wn
IMPORTANT NOTE
Olé Touchpads
and VIA! Touch Panels
Use the correct power
supply connected to the front
of the SPP for the number
of Olé Touchpads and VIA!
Touch Panels in the system.
Olé = 150mA
VIA! = 1A
PWR1 = 1.5A
PWR4 = 4A
PWR10 = 10A