Elan S128P Installation Manual page 102

Multi-room a/v controller
Table of Contents

Advertisement

S128P
INSTALLATION MANUAL
Query:
&S12,SYSOFF?<cr>
Reply:
&S12,SYSOFF,a<cr>
Parameters:
<cr>: carriage return: Hexadecimal 0x0D or Decimal 13
a: 0 = OFF
1 = ON
Examples:
• &S12,SYSOFF<cr> turns System off.
• &S12,SYSOFF?<cr> queries System status.
• &S12,SYSOFF,0<cr> S128P returns System is off.
TRE (Treble)
Description:
• Sets Zone zz to treble xyz.
• Increment Zone zz treble.
• Decrement Zone zz treble.
• Has no affect if zone is off.
• If sending 00, the + or - can be omitted.
Command:
&S12,TRE,zz,a<cr>
&S12,TRE,zz,xyz<cr>
Query:
&S12,TRE,zz?<cr>
Reply:
&S12,TRE,zz,xyz<cr>
Parameters:
<cr>: carriage return: Hexadecimal 0x0D or Decimal 13
zz: Zone: 01-32
a: + = Increments (plus symbol)
- = Decrements (minus symbol)
x: + Sets to positive number (plus symbol)
- Sets to negative number (minus symbol)
yz: 00 - 18
00 = Flat
Examples:
• &S12,TRE,+13,+<cr> Increments Zone 13's treble.
• &S12,TRE,02?<cr> queries Zone 2 for its treble.
• &S12,TRE,13,-03<cr> sets Zone 13's treble to -3
• &S12,TRE,13,00<cr> Zone 13 treble is flat.
Page 100
S128P.indd 100
E L A N H O M E S Y S T E M S
© ELAN Home Systems 2009 • All rights reserved.
1/15/2009 1:07:44 PM

Hide quick links:

Advertisement

Table of Contents
loading