INSTALLATION MANUAL
CPN (Component)
Description:
Switches S128P's Component in Zone zz to a specific Video Component Group a.
Command:
&S12,CPN,zz,a<cr>
Query:
&S12,CPN,zz?<cr>
Reply:
&S12,CPN,zz,a<cr>
Parameters:
<cr>: Carriage Return: Hexadecimal 0x0D or Decimal 13
zz: Zone: 01-32
a: Component group 1-5
0 = Track
Examples:
• &S12,CPN,03,2<cr> S128P's Component in Zone 3 selects Component Group 2.
• &S12,CPN,29?<cr> Queries S128P's Component in Zone 29 for selected Component Group.
• &S12,CPN,07,5<cr> S128P's Component in Zone 7 selects Component Group 5.
• &S12,CPN,02,0<cr> Notifies S128P to place S128P's Component in Zone 2 in Tracking Mode.
DND (Do Not Disturb)
Description:
• Turns specified Zone zz's DND off/on/toggle.
• Works if zone is off or on.
Command:
&S12,DND,zz,a<cr>
Query:
&S12,DND,zz?<cr>
Reply:
&S12,DND,zz,a<cr>
Parameters:
<cr>: carriage return: Hexadecimal 0x0D or Decimal 13
zz: Zone: 01-32
a: 0 = OFF
1 = ON
2 = TOG
Examples:
• &S12,DND,13,0<cr> turns Zone 13's DND off.
• &S12,DND,02?<cr> queries Zone 2's DND.
• &S12,DND,13,1<cr> turns Zone 13's DND on.
• &S12,DND,13,2<cr> toggles Zone 13's DND from on to off or off to on.