C" Punchdown Locations; Z•Pad Connections - Elan S128P Installation Manual

Multi-room a/v controller
Table of Contents

Advertisement

S128P
INSTALLATION MANUAL

"C" Punchdown Locations

Figure 3-8 shows connectivity to the "C" location and utilizing internal 12VDC power from the S128P Multi-Room
Controller.
Olé Touchpad to SPP Precision Panel (Using 12VDC from S128P)
N/C
W/BL
N/C
N/C
N/C
W/GR
BR
N/C
RS 485 Expansion
W/OR
GR
W/OR
GR
W/OR
GR
W/OR
GR
Z•Pad Connections
"C" Punchdown Locations
Figure 3-9 shows there are two methods available when connecting keypads as zone controllers in an S128P
based system. If using more than 2 keypads per location, make connections off of the SPP and use jumper wires to
punch-down to the correct location.
Method A-VNET (Using an SS1/SC-1)
Punch the 485+ (Wh/Orange) and 485- (Green) wires down to the RS 485 Expansion block located below the SS/
SC4 switch as shown on the S6/S12 Overlay.
Method B-ZNET (No SS1/SC-1)
Remove the S6/S12 Overlay. Punch the 485+ (Wh/Orange) to the 485+ location on the SPP and punch the 485-
(Green) wire to the 485- location on the SPP as shown below.
Page 32
S128P.indd 32
Blue
White/Blue
Orange
White/Orange
Cat-5
Green
White/Green
Brown
White/Brown
White/Orange
Green
White/Orange
Green
White/Orange
Green
White/Orange
Green
Figure 3-8: Olé Touchpad "C" Internal 12VDC Connections
E L A N H O M E S Y S T E M S
Butt splice
or equivalent
Blue
Blue
White/Blue
White/Blue (IR)
Orange
Orange(Local IR)
White/Orange
White/Orange (485+)
Green
Green (485-)
White/Green
White/Green (+12V)
Brown
Brown (GND)
White/Brown
White/Brown
IMPORTANT NOTE
Olé Touchpads, Keypads
VSEs, & IR
Each ZONE INPUT
RJ-45 Jack on the S66A
Provides 12 VDC 300mA
When using the internal 12VDC power
from the S66A, you may choose to
load each of the S66A's ZONE INPUTS
with any combination of Olé
Touchpads, IR Receivers,
or Electronic Volume Controls
as long as the total current consumption
DOES NOT EXCEED 300mA.
Olé = 150mA
Keypad w/IR Tube = 65mA
Z•025 = 85mA
Electronic Volume Control = 40mA
Additional IR Receivers = 10mA
© ELAN Home Systems 2009 • All rights reserved.
1/15/2009 1:07:04 PM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents