7.10.4

Software stroke limit function

This function prevents execution of a moving command to a position outside the upper/lower limit of the moving range
of the workpiece. The range is set using the address established by machine OPR.
RLS
Software stroke limit (lower limit)
120
Movable range of work
Software stroke limit (upper limit)
Limit switch for
emergency stop
FLS