Mitsubishi Electric MELSEC-L02SCPU User Manual page 143

Cpu module, built-in i/o function
Table of Contents

Advertisement

(c) Function
• These instructions start positioning with data stored in the device specified by
without using "Positioning data" No.1 to 10 set beforehand using the programming tool.
Ex.
Timing chart when position control is performed by setting the start device number in D0
[IPDSTRT1 D0]
IPDSTRT1(P) execution
OFF
command
Axis 1 start instruction
OFF
in execution (SM1848)
Axis 1 BUSY (SM1840)
OFF
Axis 1 positioning complete
(SM1841)
• When positioning control starts successfully, the Axis 1 busy (SM1840) turns on. (1))
• When positioning is complete, the Axis 1 busy (SM1840) turns off and Axis 1 positioning completion
(SM1841) turns on. (2)) (During speed control, causes that stop the axis include execution of the Axis stop
instruction (IPSTOP1) and aborted operation due to error detection. Accordingly, the Axis 1 positioning
completion (SM1841) does not turn on.)
• The Axis 1 positioning completion (SM1841) will turn off the next time the applicable axis is started.
• If operation cannot be started because
• If the Axis stop instruction (IPSTOP1) is executed or an error is detected during positioning, the axis
decelerates to a stop and the Axis 1 positioning completion (SM1841) does not turn on.
The number of steps is basically two.
Using values set for the specified device,
positioning is started.
Positioning data are not used.
V
Positioning execution
ON
ON
ON
1)
ON
OFF
is outside the setting range, the Axis 1 error (SM1845) turns on.
S
CHAPTER 7 POSITIONING FUNCTION
and subsequent devices,
S
Device
Control method
D0
ACC/DEC time
D1
DEC/STOP time
D2
Dwell time
D3
Command speed
D4, D5
Positioning address
D6, D7
Positioning data
No.1
to
No.10
2)
2)
7
t
141