Mitsubishi Electric MELSEC-L02SCPU User Manual page 198

Cpu module, built-in i/o function
Table of Contents

Advertisement

Pulse input
method
For counting up
CW/CCW
For counting down
For counting up
2-phase multiple of 1
For counting down
For counting up
2-phase multiple of 2
For counting down
For counting up
2-phase multiple of 4
For counting down
When a pulse input mode has been set to "1-Phase Multiple of 1 (A Phase Only)" or "1-Phase Multiple of 2 (A Phase Only)",
the input signal of phase B can be used for other functions, such as general-purpose input function other than the interrupt
input function.
196
Count timing
Counts on the rising edge () of A.
A
B is off.
B
A is off.
A
Counts on the rising edge () of B.
B
A
Counts on the rising edge () of A while B is off.
B
A
Counts on the falling edge () of A while B is off.
B
Counts on the rising edge () of A while B is off.
A
Counts on the falling edge () of A while B is on.
B
Counts on the rising edge () of A while B is on.
A
Counts on the falling edge () of A while B is off.
B
Counts on the rising edge () of A while B is off.
Counts on the falling edge () of A while B is on.
A
Counts on the rising edge () of B while A is on.
Counts on the falling edge () of B while A is off.
B
Counts on the rising edge () of A while B is on.
Counts on the falling edge () of A while B is off.
A
Counts on the rising edge () of B while A is off.
Counts on the falling edge () of B while A is on.
B

Hide quick links: