Chapter 6 Power meter and Source options of the OTDR Modules

Storing and reloading results

Figure 64
Measurement of the fiber under test
Equipment (1)
OTDR Module:
Source port
Measurement using a mode conditioner
To perform an Insertion Loss measurement with a Source that is compliant to IEC
61280-4-1 Ed2 Standard on encircled flux, it is recommended to use a mode conditioner
after the OTDR Source port.
Once the Source on T-BERD/MTS or SmartOTDR (1) and the Powermeter on T-BERD/
MTS or SmartOTDR (2) are referenced in loopback or side-by-side mode:
1
Connect the Multimode source (1) to the mode conditioner
2
Connect the Powermeter port (2) to the jumper
3
Connect extremities of the mode conditioner and jumper to the fiber under test
using the appropriate method (ex. keying mechanism for FC/PC types).
Figure 65
Measurement of the Insertion Loss with a mode conditioner
Mode
Equipment (1)
conditioner
OTDR
Multimode
Source port
4
On equipment (1) select Laser On to activate the light source.
Storing and reloading results

File Setup

Click on the button F
220
for a complete description of all parameters, options and the explorer.
112
Fiber Under Test
Jumper
Fiber Under Test
to access the
File
ILE
User Manual
setup. See
"Description of the explorer" page
77000010208 Rev. 012
Equipment (2)
Mainframe
Power meter port
Jumper
Equipment (2)
Mainframe
Power meter
port