OTDR Technical specifications for SmartOTDR
OTDR Optical Interfaces
Switchable optical connectors: FC, LC, SC
OTDR Optical characteristics
Laser safety class (21 CFR)
Distance units
Group index range
Number of data points
Distance measurement
Display range
Cursor resolution
Sampling resolution
Accuracy
Characteristics of reflectometry measurements
Distance measurement
•
Automatic or Dual cursor
•
Distance displayed takes into account the calibration of the refractive index of the
fiber.
•
Index adjustable from 1,30000 to 1,70000 in steps of 0,00001
•
Resolution of display: 1 cm max.
•
Resolution of cursor: 1 cm max.
•
Spacing of measurement points: from 4 cm, with up to 256 000 acquisition points.
•
Accuracy: ± 1m± sampling resolution ±1.10
(excluding errors of calibration of refractive index of the fiber).
•
Display span: 0.1 km m to 260 km for single mode
1.300000 to 1.700000 in 0.00001 steps
±1 m ±sampling resolution ±1.10–5 * x distance
User Manual
Chapter 13 Technical specifications
OTDR Technical specifications for SmartOTDR
Class 1
Kilometer, meter, feet, and miles
Up to 256,000 data points
Automatic or dual cursor
0.1 km to 260 km for single-mode
1 cm
4 cm for single-mode
(Excluding group index uncertainties)
-5
x distance
77000010208 Rev. 012