Configuring The Alarm Parameters; Configuring The Measurement Parameters; Configuring The Link Parameters - Viavi T-BERD/MTS 2000 User Manual

Otdr functions, options and software applications
Hide thumbs Also See for T-BERD/MTS 2000:
Table of Contents

Advertisement

Figure 67
Configuration of power measurement

Configuring the alarm parameters

Alarm
Min and max thresholds
NOTE
To copy one value of the Lower or/and Upper threshold for all wavelengths,
select the reference value and click on

Configuring the Measurement parameters

In the Setup page, press Measur't soft key (if one parameter is selected in the current
screen, press Top Menu soft key to display the right menu keys and click on Measur't)
Lambda

Configuring the Link parameters

In the Setup page, press Link soft key (if one parameter is selected in the current
screen, press Top Menu soft key to display the right menu keys and click on Link).
115
Chapter 6 Power meter and Source options of the OTDR Modules
Activation of the Alarm function: any result below the lower
threshold or above the upper threshold will be displayed in red
on the Results page.
Choice of lower and upper thresholds for each available
wavelength, from -60 to +40 dBm.
click to toggle between 1490/1550 nm and 1490/1578 nm.
User Manual
Terminated PON Powermeter (SmartOTDR only)
Update for All
77000010208 Rev. 012
See OTDR chapter:
"Configuring the File
parameters" on page 44
Wavel..