Lcb-Lens Motor Calibration; Lho-Lens Horizontal Position Adjustment - Christie Boxer 4K Technical Reference

Table of Contents

Advertisement

Examples
Get the current wired jack enabled state:
(KEN+WIRE?)
Disable the front IR sensor:
(KEN+FRNT 0)
Disable the rear IR sensor:
(KEN+REAR 1)
LCB–Lens Motor Calibration
Calibrates all of the lens motors.
This command is only enabled when the projector is on.
Commands
Command
Description
LCB 1
Runs calibration on all lens motors.
LCB+HOME
Moves all lens motors back to the center flag for each axis and sets
their respective positions to 0.
LCB+ZOOM 1
Calibrates the zoom motor.
Examples
Start calibration:
(LCB 1)
Move the lens back to the home position:
(LCB+HOME)
LHO–Lens Horizontal Position Adjustment
Sets the lens horizontal location to an absolute position.
This command is only available when the projector is on.
Commands
Command
Description
LHO <position>
Adjusts the horizontal location of the lens to
the specified position. The position is
persistent across AC cycles.
Boxer 4K Serial API Commands Technical Reference
020-101697-05 Rev. 1 (07-2017)
Copyright
2017 Christie Digital Systems USA Inc. All rights reserved.
©
Serial API commands
Values
Values
33