Flow Control - Christie Boxer 4K Technical Reference

Table of Contents

Advertisement

Error code
Description
6
Channel not found
7
Command not executed
8
Checksum error
9
Unknown request
10
Error receiving serial data
101
Control not found
102
Subcontrol not found
103
Wrong control type
104
Invalid value

Flow control

Normally messages can be sent to the projector before processing of earlier messages is complete—
Boxer 4K stores messages in a buffer until ready to process. However, if a series of messages is sent,
Boxer 4K may not be able to process them as fast as they arrive and the buffer becomes full.
If this happens, Boxer 4K sends the 13h (Xoff) code to instruct the controller (or any devices
preparing to transmit) to cease transmission. At this point, the controller must respond immediately
and send no more than 10 extra characters or they may be lost (such as, Boxer 4K can accommodate
the receipt of up to 10 more bytes after it sends 13h (Xoff)). When the buffer is once again available,
Boxer 4K sends a 11h (Xon) command to resume transmission.
Xon and Xoff controls apply to both directions of communication. Boxer 4K does not send more than
three characters after it has received a 13h (Xoff) code.
Boxer 4K Serial API Commands Technical Reference
020-101697-05 Rev. 1 (07-2017)
Copyright
2017 Christie Digital Systems USA Inc. All rights reserved.
©
Communicating with Boxer 4K
Error code
Description
110
Communication timeout
111
Communications failure
112
Failed to set hardware
113
Bad file
114
Memory failure
115
Not implemented
116
Invalid security
117
Invalid access group
118
System busy - Try again later