(RAL+PRTC 1)
SHU–Shutter
Opens and closes the shutter.
The command can also be used check if the shutter is currently opened or closed. It can also return an
incorrect result if the shutter was manually opened or closed.
Commands
Command
Description
SHU?
Gets the state of the shutter.
SHU <0 | 1>
Opens or closes the shutter.
Examples
Get the state of the shutter.
(SHU?)
Result:
(SHU!0)
Indicates the shutter is open.
Open the shutter.
(SHU 0)
Close the shutter.
(SHU 1)
SIN–Select Input
Selects the active input.
Commands
Command
Description
SIN <input>
Selects a set of inputs based on the selected port
configuration. This command is only available if video
electronics are on. (Saved value)
SIN?L
Returns a list of available inputs to select based on the
selected port configuration. (Read-only)
Boxer 4K Serial API Commands Technical Reference
020-101697-05 Rev. 1 (07-2017)
Copyright
2017 Christie Digital Systems USA Inc. All rights reserved.
©
Serial API commands
Values
0 = Opens the shutter
1 = Closes the shutter (Default)
Values
The list of available values is
dynamic. Run SIN?L to retrieve
the currently available list.