LPL–Lamp Life
Sets the expected lamp life in hours. If the lamp run time exceeds this value, a warning is displayed in
the status system.
The lamp run time is equal to the lamp's original lamp hours plus the amount of time it has been on
while installed in the projector.
Commands
Command
Description
LPL <hours>
Sets the number of hours before a warning is displayed
in the status system about the lamp needing to be
replaced. (Saved value)
Examples
LPP–Lamp Power
Sets the amount of power going to the lamp.
Commands
Command
Description
LPP <power>
Sets the power going to the lamp, in watts.
(Saved value)
LPP?m
Returns the minimum and maximum power
allowed for the current lamp. (Read-only)
Examples
Set the light source to 9:
(LPP 0)
LVO–Lens Vertical Position Adjustment
Sets the lens vertical location to an absolute position.
This command is only enabled when the projector is on.
Boxer 4K Serial API Commands Technical Reference
020-101697-05 Rev. 1 (07-2017)
Copyright
2017 Christie Digital Systems USA Inc. All rights reserved.
©
Serial API commands
Values
Any positive number
0 = Disables the lamp end-of-life
check (Default)
Values
power = Number of watts to run the lamp at
This is dependent on the type of lamp being
used.